 Test Running

² Before the test, it shall firstly check if the circuit grounding is reliable,

the three phase power supply is consist with the local voltage

requirements. Water pressure> 2bar - <4bar. Water temperature

10 .

l Operate the gas switch to check if the machine moves backward ro

forwards freely.

l Start the cooling water systems, adjust the water flow in the press

rollers and cooling roller, and check if the spatula is clean.

l Check if the scraper of the crushing roller is clean; if there is debris,

clean in time to prevent to scratch the belt.

l Open the belt cooling water to check whether all the nozzles work

well.

l Start the belt driver and the roller driver, check the rotation

direction of the press roller, adjust the reasonable rotation speed

ratio [Check the record].

l Start the cooling water systems, adjust the water flow in the rollers.

l Check the rotating direction of the roller.

l Check if the limit switch on the shields is normal. [Open the shield,

the equipment will stop]

l Check if the emergency stop button on the side of the rollers is in

place. [Press the button, the roller will rotate reversely; press the

botton again, the roller will stop ]

l Adjust the gap between the pressure roller[1-1.5mm]

l Turn off electric switches, check if the equipment can be safely

shutdown.